{"id":685,"date":"2025-12-10T11:21:42","date_gmt":"2025-12-10T10:21:42","guid":{"rendered":"https:\/\/www.valfonta.com\/blog\/what-difference-between-safety-valve-and-relief-valve\/"},"modified":"2026-10-15T12:11:10","modified_gmt":"2026-10-15T10:11:10","slug":"what-difference-between-safety-valve-and-relief-valve","status":"publish","type":"post","link":"https:\/\/www.valfonta.com\/en\/blog\/what-difference-between-safety-valve-and-relief-valve\/","title":{"rendered":"What is the difference between a safety valve and a pressure relief valve?"},"content":{"rendered":"<div class=\"wp-block-group vf-raiz vf-pl-articulo is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-cat-wrap is-layout-flow wp-block-group-is-layout-flow\"><article class=\"wp-block-group vf-pdp vf-post is-layout-flow wp-block-group-is-layout-flow\"><nav class=\"wp-block-group vf-breadcrumbs vfa-aria-label--Breadcrumbs is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><a href=\"\/en\/\">Home<\/a><span class=\"vf-sep\">\u203a<\/span><a href=\"\/en\/blog\/\">Blog<\/a><span class=\"vf-sep\">\u203a<\/span><span aria-current=\"page\">What is the difference between a safety valve and a pressure relief valve?<\/span><\/p><\/nav><header class=\"wp-block-group vf-post-head is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-pdp-eyebrow wp-block-paragraph\"><a href=\"\/en\/safety-valves\/\">Safety valves<\/a><\/p><h1 class=\"wp-block-heading\">What is the difference between a safety valve and a pressure relief valve?<\/h1><p class=\"vf-post-meta wp-block-paragraph\"><span>By Valfonta<\/span><span><time datetime=\"2026-09-29\">Updated September 29, 2026<\/time><\/span><span>9 min read<\/span><\/p><\/header><figure class=\"wp-block-image size-full vf-post-hero is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/pasted-image-0-1.png\" alt=\"What is the difference between a safety valve and a pressure relief valve?\" class=\"wp-image-227\" width=\"1200\" height=\"514\"\/><\/figure><div class=\"wp-block-group vf-post-grid is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-post-body is-layout-flow wp-block-group-is-layout-flow\"><aside class=\"wp-block-group vf-post-summary vfa-aria-label--In%20summary is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-t wp-block-paragraph\">In summary<\/p><p class=\"wp-block-paragraph\">The difference between a safety valve and a pressure relief valve lies in how it opens and in the fluid: a safety valve pops fully open (100%) with gases and steam, while a relief valve opens gradually and proportionally with liquids. A safety valve prevents explosions in boilers, compressors, or reactors and recloses below its opening pressure (blowdown). A relief valve protects pumps and piping and prevents water hammer. In the Valfonta range, the S3 is the relief valve and the JAS is the boiler safety valve.<\/p><\/aside><details class=\"wp-block-details vf-post-toc-m is-layout-flow wp-block-details-is-layout-flow\"><summary>Article contents<\/summary><ol class=\"wp-block-list\"><li><a href=\"#definiciones-tecnicas-que-es-que\">Technical definitions: what is what?<\/a><\/li><li><a href=\"#las-3-diferencias-principales-entre-seguridad-y-alivio\">The 3 main differences between safety and relief valves<\/a><\/li><li><a href=\"#tabla-comparativa-rapida-valvula-de-seguridad-vs-alivio\">Quick comparison table: safety valve vs. relief valve<\/a><\/li><li><a href=\"#cuando-utilizar-cada-valvula-ejemplos-de-aplicacion\">When to use each valve: application examples<\/a><\/li><li><a href=\"#preguntas\">Frequently asked questions<\/a><\/li><\/ol><\/details><p class=\"wp-block-paragraph\">Although the two terms are often used interchangeably in industry, there is a fundamental technical distinction between them. The main difference lies in the <strong>opening mechanism<\/strong> and the <strong>type of fluid<\/strong> they are designed for.<\/p><p class=\"wp-block-paragraph\">In short: a <strong>safety valve<\/strong> is designed to pop open and release a large amount of fluid immediately (usually gases or steam) to prevent an explosion. A <strong>relief valve<\/strong>, by contrast, opens gradually and in proportion to the pressure rise (usually for liquids) to keep the system stable without damaging it.<\/p><p class=\"wp-block-paragraph\">Understanding this difference is vital not only for plant efficiency but also for operator safety and equipment integrity. Below, we break down each concept from a technical standpoint.<\/p><h2 class=\"wp-block-heading\" id=\"definiciones-tecnicas-que-es-que\"><strong>Technical definitions: what is what?<\/strong><\/h2><p class=\"wp-block-paragraph\">To choose the right protection device, we first need to understand how each one works internally. At Valfonta we manufacture both types, and the wrong choice can lead to system failures or safety risks. We review all the options in our guide to <a href=\"\/en\/blog\/pressure-relief-valve-how-to-choose-it\/\">pressure relief devices<\/a>.<\/p><h3 class=\"wp-block-heading\" id=\"valvula-de-alivio-de-presion\"><strong>Pressure relief valve <\/strong><\/h3><p class=\"wp-block-paragraph\">A pressure relief valve is a <strong>proportional-action<\/strong> device. It is designed mainly for systems with <strong>incompressible fluids<\/strong>, that is, liquids such as water, thermal oils, or fuels.<\/p><p class=\"wp-block-paragraph\">Unlike a safety valve, it opens gradually. When the pressure exceeds the set limit, the valve disc begins to lift slightly. If the pressure keeps rising, the valve opens further; if the pressure stabilizes, the valve stops opening. It does not discharge all the fluid at once, only the amount needed to bring the pressure back to a safe level. With liquids, this is crucial to avoid the destructive \u201cwater hammer\u201d that would occur if the flow were shut off or opened suddenly.<\/p><ul class=\"wp-block-list\"><li><strong>Main purpose:<\/strong> Process control and protection of components (pumps, piping).<\/li><li><strong>Behavior:<\/strong> Modulating and controlled.<\/li><\/ul><h3 class=\"wp-block-heading\" id=\"valvula-de-seguridad\"><strong> Safety valve <\/strong><\/h3><p class=\"wp-block-paragraph\">A safety valve is a <strong>fast-acting<\/strong> or \u201csudden-opening\u201d device (<i>pop action<\/i>). It is designed specifically for service with <strong>compressible fluids<\/strong>, such as steam, compressed air, or technical gases.<\/p><p class=\"wp-block-paragraph\">It works in a binary way: when the internal system pressure reaches the set point (set pressure), the valve does not open little by little. Instead, it opens fully (to 100% of its lift capacity) almost instantly. That is why this value must be checked periodically: we explain it in why you should audit the set pressure of relief valves.<\/p><p class=\"wp-block-paragraph\">This makes it possible to discharge a large mass of gas in the shortest possible time, reducing the pressure drastically and preventing the vessel or pipe from bursting.<\/p><ul class=\"wp-block-list\"><li><strong>Main purpose:<\/strong> Ultimate safety (protection of life and critical equipment).<\/li><li><strong>Behavior:<\/strong> On\/off.<\/li><\/ul><h2 class=\"wp-block-heading\" id=\"las-3-diferencias-principales-entre-seguridad-y-alivio\"><strong>The 3 main differences between safety and relief valves<\/strong><\/h2><p class=\"wp-block-paragraph\">Beyond their definitions, three technical factors clearly set these two valves apart. Understanding these nuances will help you determine which one your installation needs.<\/p><h3 class=\"wp-block-heading\" id=\"1-el-tipo-de-fluido-compresible-vs-incompresible\"><strong>1. Fluid type: compressible vs. incompressible<\/strong><\/h3><p class=\"wp-block-paragraph\">This is the golden rule. <strong>Safety valves<\/strong> are used almost exclusively with <strong>gases and steam<\/strong> (compressible fluids). This is because gases, as they build up pressure, store an enormous amount of energy that can be explosive. <\/p><p class=\"wp-block-paragraph\"><strong>Relief valves<\/strong>, by contrast, are used with <strong>liquids<\/strong> (incompressible fluids). Liquids do not compress in the same way, so the pressure rise is due more to pumping force or thermal expansion than to compression of the volume, which calls for gentler handling.<\/p><h3 class=\"wp-block-heading\" id=\"2-el-mecanismo-de-apertura-disparo-vs-proporcional\"><strong>2. Opening mechanism: pop vs. proportional<\/strong><\/h3><p class=\"wp-block-paragraph\">The <strong>safety valve<\/strong> is designed to open fully as soon as the set pressure is reached. It has no \u201cin-between positions\u201d; it aims to release the maximum amount of mass in the shortest possible time to prevent a disaster. <\/p><p class=\"wp-block-paragraph\">The <strong>relief valve<\/strong>, on the other hand, operates <strong>proportionally<\/strong>. It opens gradually as the pressure rises above the set pressure. If the pressure rises 10%, the valve opens 10%. This avoids sudden changes that could damage the piping (water hammer) in hydraulic systems.<\/p><h3 class=\"wp-block-heading\" id=\"3-el-punto-de-reajuste-cierre\"><strong>3. The reseat point (closing)<\/strong><\/h3><p class=\"wp-block-paragraph\">Once the pressure has dropped to a safe level, the <strong>safety valve<\/strong> closes again, but it usually does so at a pressure significantly lower than the opening pressure (this is known as <i>blowdown<\/i>) to prevent the valve from \u201cchattering,\u201d or opening and closing repeatedly in rapid succession. <\/p><p class=\"wp-block-paragraph\">The <strong>relief valve<\/strong> tends to close as soon as the pressure returns to the set level, acting more like a limit regulator than an emergency discharge device.<\/p><h2 class=\"wp-block-heading\" id=\"tabla-comparativa-rapida-valvula-de-seguridad-vs-alivio\"><strong>Quick comparison table: safety valve vs. relief valve<\/strong><\/h2><p class=\"wp-block-paragraph\">To make quick selection easier, we have summarized the technical characteristics of both devices in the following table:<\/p><div class=\"wp-block-group vf-tbl-wrap is-layout-flow wp-block-group-is-layout-flow\"><figure class=\"wp-block-table vf-post-table\"><table><thead><tr><th><strong>Characteristic<\/strong><\/th><th><strong>Safety valve <\/strong><\/th><th><strong>Relief valve<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Main fluid<\/strong><\/td><td>Gases, steam, air <\/td><td>Liquids, water, oil <\/td><\/tr><tr><td><strong>Opening type<\/strong><\/td><td>Sudden \/ Instantaneous (<i>Pop action<\/i>) <\/td><td>Gradual \/ Proportional<\/td><\/tr><tr><td><strong>Purpose<\/strong><\/td><td>Safety against explosion or critical failure<\/td><td>Overpressure control and stability<\/td><\/tr><tr><td><strong>Prevention<\/strong><\/td><td>Prevents the vessel from bursting<\/td><td>Prevents damage to pumps and piping<\/td><\/tr><tr><td><strong>Example of use<\/strong><\/td><td>Steam boilers, reactors, gas tanks<\/td><td>Hydraulic circuits, fuel lines<\/td><\/tr><\/tbody><\/table><\/figure><\/div><h2 class=\"wp-block-heading\" id=\"cuando-utilizar-cada-valvula-ejemplos-de-aplicacion\"><strong>When to use each valve: application examples<\/strong><\/h2><p class=\"wp-block-paragraph\">Understanding the theory is important, but seeing how these devices behave in real-world situations is what makes the difference when designing a safe installation. Here we look at the most common scenarios for each type.<\/p><h3 class=\"wp-block-heading\" id=\"casos-de-uso-para-valvula-de-alivio-de-presion\"><strong>Use cases for a pressure relief valve<\/strong><\/h3><p class=\"wp-block-paragraph\">Here the goal is to protect the machinery (pumps, piping) and keep the process running without sudden interruptions.<\/p><div class=\"wp-block-group vf-t-ul is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Liquid pumping systems:<\/strong> Imagine a pump driving water or oil through a pipe when, suddenly, a downstream shutoff valve closes. The pump would keep pushing, raising the pressure until the pipe bursts or the motor burns out. This is where a relief valve is installed in a <i>bypass<\/i>: as the pressure rises, it opens gradually and recirculates the liquid back to the tank or to the pump suction. If what needs protecting is the tank itself against overpressure or vacuum, <a href=\"\/en\/product\/alper-atmospheric-valves\/\">atmospheric valves such as the ALPER<\/a> are used.<\/p><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Hydraulic and lubrication circuits:<\/strong> In heavy machinery, when a cylinder reaches the end of its stroke, the oil pressure rises. The relief valve lets the oil flow back to the tank, keeping the pressure stable and preventing damage to the seals.<\/p><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Fuel lines:<\/strong> To prevent overpressure caused by thermal expansion (if fuel trapped in a section of pipe heats up), a small relief valve releases the small amount of liquid needed to relieve the stress.<\/p><\/div><\/div><h3 class=\"wp-block-heading\" id=\"casos-de-uso-para-valvula-de-seguridad\"><strong>Use cases for a safety valve<\/strong><\/h3><p class=\"wp-block-paragraph\">Remember that here we are looking for an <strong>immediate reaction<\/strong> to prevent a catastrophic failure in vessels that contain stored energy (compressed gases or steam).<\/p><div class=\"wp-block-group vf-t-ul is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Steam boilers:<\/strong> This is the textbook example. If the steam pressure exceeds the boiler\u2019s design limit, the safety valve \u201cpops,\u201d opening to 100%. This discharges the steam instantly to keep the boiler from exploding. For boilers and steam or hot water tanks, Valfonta manufactures the <a href=\"\/en\/product\/safety-valves-for-boilers-jas\/\">JAS boiler safety valve<\/a>, with instantaneous full opening.<\/p><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Compressors and air receivers:<\/strong> In a compressed air tank, if the pressure switch fails and the compressor keeps pumping in air, the pressure will rise dangerously. The safety valve acts as the last line of defense, releasing the excess air all at once.<\/p><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Chemical reactors (gas phase):<\/strong> In exothermic processes that generate gas rapidly, a valve is needed that can evacuate that volume of gas as fast as it is generated in order to maintain the integrity of the reactor.<\/p><\/div><\/div><p class=\"wp-block-paragraph\">See our ranges of <a href=\"\/en\/pressure-relief-valve\/\">pressure relief valves<\/a> and <a href=\"\/en\/safety-valves\/\">safety valves<\/a>, or the datasheet for the <a href=\"\/en\/product\/pressure-relief-valve-s3\/\">S3 pressure relief valve<\/a>.<\/p><h3 class=\"wp-block-heading\" id=\"necesita-asesoramiento-personalizado-de-nuestros-tecnicos\"><strong> Do you need personalized advice from our engineers?<\/strong><\/h3><p class=\"wp-block-paragraph\">Choosing between a safety valve and a relief valve is not just a matter of terminology, but of operational safety and efficiency. <\/p><p class=\"wp-block-paragraph\">Mistaking a gas application for a liquid one can have serious consequences for your installation.<\/p><p class=\"wp-block-paragraph\">At <strong>Valfonta<\/strong>, we manufacture and distribute both solutions, complying with current regulations and adapting to the specific needs of your fluid, pressure, and temperature.<\/p><p class=\"wp-block-paragraph\">If you are unsure which model to install on your steam, gas, or liquid line, don\u2019t take chances. <\/p><p class=\"wp-block-paragraph\"><strong>Contact our technical team<\/strong> for a customized study and to ensure optimal protection of your equipment.<\/p><figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/logo.png\" alt=\"Steam pressure reducing valve\" class=\"wp-image-254\" width=\"332\" height=\"83\" loading=\"lazy\"\/><\/figure><section id=\"preguntas\" class=\"wp-block-group vf-post-faq is-layout-flow wp-block-group-is-layout-flow\"><h2 class=\"wp-block-heading\">Frequently asked questions<\/h2><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Can I use a safety valve for water or other liquids?<\/summary><div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><p class=\"wp-block-paragraph\">It is not recommended. If you use a sudden-opening safety valve in a water system, the massive, sudden flow when it pops open can cause violent \u201cwater hammer.\u201d This creates shock waves that can break pipes and supports. For liquids, a proportional-opening relief valve is always preferable.<\/p><\/div><\/details><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Are the terms safety and relief interchangeable?<\/summary><div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><p class=\"wp-block-paragraph\">Colloquially, many technicians use them interchangeably. From a regulatory and engineering standpoint, however, they are not. A <i>safety valve<\/i> has fast-opening characteristics certified for gases, while a <i>relief valve<\/i> has a gradual-opening characteristic for liquids.<\/p><\/div><\/details><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>What is set pressure?<\/summary><div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><p class=\"wp-block-paragraph\">It is the exact pressure point at which the valve is set to begin opening. In safety valves, full opening occurs almost immediately after this point is exceeded. In relief valves, full opening requires additional overpressure (generally 10% or 25% above the set pressure).<\/p><\/div><\/details><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>What is a safety relief valve?<\/summary><div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><p class=\"wp-block-paragraph\">It is a hybrid term used to describe a versatile valve that can work either way depending on the application. It generally refers to a valve that opens rapidly (safety type) when used with gases, but can also open proportionally (relief type) when installed in a liquid system.<\/p><\/div><\/details><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Does the valve close at exactly the same pressure at which it opened?<\/summary><div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><p class=\"wp-block-paragraph\">In <strong>relief valves<\/strong>, yes; they tend to close as soon as the pressure drops to the set level (<i>set point<\/i>). In <strong>safety valves<\/strong>, no; they need the pressure to fall significantly below the opening pressure (a margin known as <i>blowdown<\/i> or reseating differential) to ensure tight shutoff and to keep the valve from \u201cchattering\u201d or vibrating unstably.<\/p><\/div><\/details><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Where should the fluid released by each valve be discharged?<\/summary><div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><p class=\"wp-block-paragraph\">Because the <strong>safety valve<\/strong> releases toxic or hot fluid at high velocity, its outlet must always be routed to a safe location (such as a vent header or the atmosphere) where there is no backpressure to affect its popping. The <strong>relief valve<\/strong>, being part of process control, usually discharges the liquid through a return line to the storage tank or to the pump suction, recirculating the fluid without losing it.<\/p><\/div><\/details><\/section><\/div><aside class=\"wp-block-group vf-post-aside is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-post-sticky is-layout-flow wp-block-group-is-layout-flow\"><nav class=\"wp-block-group vf-post-toc vfa-aria-label--Article%20contents is-layout-flow wp-block-group-is-layout-flow\"><p class=\"wp-block-paragraph\">In this article<\/p><ol class=\"wp-block-list\"><li><a href=\"#definiciones-tecnicas-que-es-que\">Technical definitions: what is what?<\/a><\/li><li><a href=\"#las-3-diferencias-principales-entre-seguridad-y-alivio\">The 3 main differences between safety and relief valves<\/a><\/li><li><a href=\"#tabla-comparativa-rapida-valvula-de-seguridad-vs-alivio\">Quick comparison table: safety valve vs. relief valve<\/a><\/li><li><a href=\"#cuando-utilizar-cada-valvula-ejemplos-de-aplicacion\">When to use each valve: application examples<\/a><\/li><li><a href=\"#preguntas\">Frequently asked questions<\/a><\/li><\/ol><\/nav><div class=\"wp-block-group vf-post-cta is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-t wp-block-paragraph\">Do you need a safety valve?<\/p><p class=\"wp-block-paragraph\">We help you choose the right model and size for your installation.<\/p><p class=\"vf-envolt wp-block-paragraph\"><a class=\"vf-btn vf-btn--pri\" href=\"#contactar\">Request a quote<\/a><\/p><p class=\"vf-envolt wp-block-paragraph\"><a class=\"vf-btn vf-btn--sec\" href=\"\/en\/safety-valves\/\">View safety valves<\/a><\/p><p class=\"vf-tel wp-block-paragraph\">Or call <a href=\"tel:+34933720888\">933 720 888<\/a><\/p><\/div><\/div><\/aside><\/div><section id=\"valvulas\" class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><h2 class=\"wp-block-heading\">Related valves<\/h2><ul class=\"vf-rel wp-block-list\"><li><a href=\"\/en\/product\/pressure-relief-valve-s3\/\"><img decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/valvula-alivio-presion-s3-s4-perspectiva-400.webp\" alt=\"S3 pressure relief valve\" class=\"wp-image-10230\" width=\"300\" height=\"300\" loading=\"lazy\"><b>S3 pressure relief valve<\/b><span>From DN15 to DN150, PN40, set pressure up to 20 barg and 220 \u00b0C.<\/span><\/a><\/li><li><a href=\"\/en\/pressure-relief-valve\/\"><img decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/valvula-alivio-presion-s3-s4-perspectiva-400.webp\" alt=\"Pressure relief valves\" class=\"wp-image-10230\" width=\"300\" height=\"300\" loading=\"lazy\"><b>Pressure relief valves<\/b><span>S1\u2013S4 and PRV53\u201355 range, from DN15 to DN150 and set pressure up to 20 barg.<\/span><\/a><\/li><li><a href=\"\/en\/product\/progressive-opening-safety-valve\/\"><img decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/alivio-368-700x700-1.jpg\" alt=\"368\u2013371 safety valve\" class=\"wp-image-196\" width=\"300\" height=\"300\" loading=\"lazy\"><b>368\u2013371 safety valve<\/b><span>Progressive opening, in brass\/bronze, from 3\/8\u2033 to 3\u2033.<\/span><\/a><\/li><\/ul><p class=\"vf-post-more wp-block-paragraph\"><a href=\"\/en\/safety-valves\/\">View all safety valves \u2192<\/a><\/p><\/section><section id=\"articulos\" class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><h2 class=\"wp-block-heading\">Related articles<\/h2><div class=\"wp-block-group vf-post-cards vf-t-ul is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-amb-enllac is-layout-flow wp-block-group-is-layout-flow\"><figure class=\"wp-block-image vf-img-suelta\"><img decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/valvula-alivio-presion.png\" alt=\"\" class=\"wp-image-233\" width=\"400\" height=\"225\" loading=\"lazy\"><\/figure><div class=\"wp-block-group vf-in is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><small>Pressure relief valves<\/small><b>What are the main features of a pneumatic pressure relief valve?<\/b><span>5 min read<\/span><\/p><\/div><p class=\"vf-enllac wp-block-paragraph\"><a class=\"vf-enllac-estirat\" href=\"\/en\/blog\/pneumatic-pressure-relief-valve\/\" aria-label=\"Pressure relief valves What are the main features of a pneumatic pressure relief valve? 5 min read\"><\/a><\/p><\/div><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-amb-enllac is-layout-flow wp-block-group-is-layout-flow\"><figure class=\"wp-block-image vf-img-suelta\"><img decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/valvula-alivio-presion.png\" alt=\"\" class=\"wp-image-233\" width=\"400\" height=\"225\" loading=\"lazy\"><\/figure><div class=\"wp-block-group vf-in is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><small>Pressure relief valves<\/small><b>Discover the Valfonta Model S3 hydraulic pressure relief valve<\/b><span>5 min read<\/span><\/p><\/div><p class=\"vf-enllac wp-block-paragraph\"><a class=\"vf-enllac-estirat\" href=\"\/en\/blog\/hydraulic-pressure-relief-valve\/\" aria-label=\"Pressure relief valves Discover the Valfonta Model S3 hydraulic pressure relief valve 5 min read\"><\/a><\/p><\/div><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-amb-enllac is-layout-flow wp-block-group-is-layout-flow\"><figure class=\"wp-block-image vf-img-suelta\"><img decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/alivio-de-presionpara-agua-gases-y-vapor1.jpg\" alt=\"\" class=\"wp-image-167\" width=\"400\" height=\"225\" loading=\"lazy\"><\/figure><div class=\"wp-block-group vf-in is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><small>Pressure relief valves<\/small><b>Pressure relief valve for water, steam, and gases: definition and operation<\/b><span>10 min read<\/span><\/p><\/div><p class=\"vf-enllac wp-block-paragraph\"><a class=\"vf-enllac-estirat\" href=\"\/en\/blog\/water-pressure-relief-valve\/\" aria-label=\"Pressure relief valves Pressure relief valve for water, steam, and gases: definition and operation 10 min read\"><\/a><\/p><\/div><\/div><\/div><\/section><section id=\"contactar\" class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-quote is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><h2 class=\"wp-block-heading\">Can we help with your installation?<\/h2><p class=\"wp-block-paragraph\">Tell us the fluid, the inlet and outlet pressures, the temperature, and the flow rate, and we will recommend the right valve.<\/p><p class=\"vf-pdp-contact wp-block-paragraph\">You can also call <a href=\"tel:+34933720888\">933 720 888<\/a> or email <a href=\"mailto:valfonta@valfonta.com\">valfonta@valfonta.com<\/a>.<\/p><\/div>\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f535-o1\" lang=\"en-US\" dir=\"ltr\" data-wpcf7-id=\"535\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/en\/wp-json\/wp\/v2\/posts\/685#wpcf7-f535-o1\" method=\"post\" class=\"wpcf7-form init vf-form wpcf7-acceptance-as-validation\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\" toolname=\"consulta_contacto\" tooldescription=\"Send an enquiry to Valfonta, industrial valve manufacturer; a member of the team will reply.\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"535\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.2.5\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f535-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/><input type=\"hidden\" name=\"_vf_t\" value=\"1795901413.5f50901c2e12e1c5\" \/>\n<\/fieldset>\n<label>Name *<span class=\"wpcf7-form-control-wrap\" data-name=\"nombre\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" autocomplete=\"name\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"nombre\" \/><\/span><\/label><label>Company<span class=\"wpcf7-form-control-wrap\" data-name=\"empresa\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text\" autocomplete=\"organization\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"empresa\" \/><\/span><\/label><label>Email *<span class=\"wpcf7-form-control-wrap\" data-name=\"email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" autocomplete=\"email\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"email\" name=\"email\" \/><\/span><\/label><label>Phone<span class=\"wpcf7-form-control-wrap\" data-name=\"telefono\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-tel wpcf7-text wpcf7-validates-as-tel\" autocomplete=\"tel\" aria-invalid=\"false\" value=\"\" type=\"tel\" name=\"telefono\" \/><\/span><\/label><label class=\"vf-full\">Reason for your inquiry<span class=\"wpcf7-form-control-wrap\" data-name=\"motivo\"><select class=\"wpcf7-form-control wpcf7-select\" aria-invalid=\"false\" name=\"motivo\"><option value=\"\">Select<\/option><option value=\"Request a quote\">Request a quote<\/option><option value=\"Technical advice on choosing a valve\">Technical advice on choosing a valve<\/option><option value=\"Spare parts or repair\">Spare parts or repair<\/option><option value=\"Documentation or certificates\">Documentation or certificates<\/option><option value=\"Other\">Other<\/option><\/select><\/span><\/label><label class=\"vf-full\">Message *<span class=\"wpcf7-form-control-wrap\" data-name=\"mensaje\"><textarea cols=\"40\" rows=\"5\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Tell us what you need: fluid, pressures, flow rate, model, or serial number\u2026\" name=\"mensaje\"><\/textarea><\/span><\/label><label class=\"vf-chk vf-full\"><span class=\"wpcf7-form-control-wrap\" data-name=\"privacidad\"><span class=\"wpcf7-form-control wpcf7-acceptance\"><span class=\"wpcf7-list-item\"><input type=\"checkbox\" name=\"privacidad\" value=\"1\" aria-invalid=\"false\" \/><\/span><\/span><\/span> <span>I have read and accept the <a href=\"\/en\/privacy-policy\/\">privacy policy<\/a> *<\/span><\/label><input class=\"wpcf7-form-control wpcf7-submit has-spinner vf-btn vf-btn--pri\" type=\"submit\" value=\"Send message\" \/><span class=\"vf-hp\" aria-hidden=\"true\"><label>Web <input type=\"text\" name=\"vf_web\" value=\"\" tabindex=\"-1\" autocomplete=\"off\" toolparamdescription=\"Campo de control: d\u00e9jalo vac\u00edo\"><\/label><\/span><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n\n<\/div><\/section><div class=\"wp-block-group vf-pdp-bar is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><a class=\"vf-btn vf-btn--sec\" href=\"tel:+34933720888\">Call<\/a><a class=\"vf-btn vf-btn--pri\" href=\"#contactar\">Request a quote<\/a><\/p><\/div><\/article><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>The difference between a safety valve and a pressure relief valve lies in how it opens and in the fluid: a safety valve pops fully open (100%) with gases and steam, while a relief valve opens gradually and proportionally with liquids.<\/p>\n","protected":false},"author":1,"featured_media":227,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_generate-full-width-content":"true","_generate-disable-headline":"true","rank_math_title":"Difference between safety and relief valves | Valfonta","rank_math_description":"Is there a difference between a safety valve and a relief valve? Find out on our website. Take a look!","rank_math_focus_keyword":"","vf_jsonld":"[{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.valfonta.com\/#organization\",\"name\":\"Valfonta\",\"legalName\":\"Val Fonta, S.L.\",\"taxID\":\"B59935718\",\"url\":\"https:\/\/www.valfonta.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/valfonta-logo.webp\"},\"foundingDate\":\"1962\",\"email\":\"valfonta@valfonta.com\",\"telephone\":\"+34 933 720 888\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"C\/ Bronze 26, Pol. Ind. Les Guixeres\",\"postalCode\":\"08915\",\"addressLocality\":\"Badalona\",\"addressRegion\":\"Barcelona\",\"addressCountry\":\"ES\"},\"description\":\"Design, manufacture, and sale of pressure reducing valves, pressure relief valves, and control valves.\"},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.valfonta.com\/#website\",\"url\":\"https:\/\/www.valfonta.com\/en\/\",\"name\":\"Valfonta\",\"publisher\":{\"@id\":\"https:\/\/www.valfonta.com\/#organization\"},\"inLanguage\":\"en\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.valfonta.com\/en\/blog\/what-difference-between-safety-valve-and-relief-valve\/#webpage\",\"url\":\"https:\/\/www.valfonta.com\/en\/blog\/what-difference-between-safety-valve-and-relief-valve\/\",\"name\":\"Difference between safety and relief valves | Valfonta\",\"description\":\"Is there a difference between a safety valve and a relief valve? Find out on our website. Take a look!\",\"isPartOf\":{\"@id\":\"https:\/\/www.valfonta.com\/#website\"},\"about\":{\"@id\":\"https:\/\/www.valfonta.com\/#organization\"},\"inLanguage\":\"en\",\"datePublished\":\"2025-12-10T11:21:42+02:00\",\"dateModified\":\"2026-09-29T12:00:00+02:00\",\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/pasted-image-0-1.png\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.valfonta.com\/en\/blog\/what-difference-between-safety-valve-and-relief-valve\/#breadcrumb\"}},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/pasted-image-0-1.png\",\"url\":\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/pasted-image-0-1.png\",\"caption\":\"What is the difference between a safety valve and a pressure relief valve?\",\"inLanguage\":\"en\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/pasted-image-0-1.png\",\"url\":\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/pasted-image-0-1.png\",\"width\":\"1000\",\"height\":\"1000\",\"caption\":\"Pressure relief valve\",\"inLanguage\":\"en\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.valfonta.com\/en\/blog\/what-difference-between-safety-valve-and-relief-valve\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.valfonta.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\/\/www.valfonta.com\/en\/blog\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"What is the difference between a safety valve and a pressure relief valve?\",\"item\":\"https:\/\/www.valfonta.com\/en\/blog\/what-difference-between-safety-valve-and-relief-valve\/\"}]},{\"@type\":\"BlogPosting\",\"keywords\":\"Difference between a safety valve and a relief valve\",\"datePublished\":\"2025-12-10T11:21:42+02:00\",\"dateModified\":\"2026-09-29T12:00:00+02:00\",\"articleSection\":\"Safety valves\",\"publisher\":{\"@id\":\"https:\/\/www.valfonta.com\/#organization\"},\"@id\":\"https:\/\/www.valfonta.com\/en\/blog\/what-difference-between-safety-valve-and-relief-valve\/#richSnippet\",\"isPartOf\":{\"@id\":\"https:\/\/www.valfonta.com\/en\/blog\/what-difference-between-safety-valve-and-relief-valve\/#webpage\"},\"image\":{\"@id\":\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/pasted-image-0-1.png\"},\"inLanguage\":\"en\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.valfonta.com\/en\/blog\/what-difference-between-safety-valve-and-relief-valve\/#webpage\"},\"headline\":\"What is the difference between a safety valve and a pressure relief valve?\",\"name\":\"Difference between safety and relief valves | Valfonta\",\"description\":\"Is there a difference between a safety valve and a relief valve? Find out on our website. Take a look!\",\"author\":{\"@id\":\"https:\/\/www.valfonta.com\/#organization\"},\"abstract\":\"The difference between a safety valve and a pressure relief valve lies in how it opens and in the fluid: a safety valve pops fully open (100%) with gases and steam, while a relief valve opens gradually and proportionally with liquids. A safety valve prevents explosions in boilers, compressors, or reactors and recloses below its opening pressure (blowdown). A relief valve protects pumps and piping and prevents water hammer. In the Valfonta range, the S3 is the relief valve and the JAS is the boiler safety valve.\"},{\"@type\":\"FAQPage\",\"@id\":\"https:\/\/www.valfonta.com\/en\/blog\/what-difference-between-safety-valve-and-relief-valve\/#faq\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Can I use a safety valve for water or other liquids?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It is not recommended. If you use a sudden-opening safety valve in a water system, the massive, sudden flow when it pops open can cause violent \u201cwater hammer.\u201d This creates shock waves that can break pipes and supports. For liquids, a proportional-opening relief valve is always preferable.\"}},{\"@type\":\"Question\",\"name\":\"Are the terms safety and relief interchangeable?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Colloquially, many technicians use them interchangeably. From a regulatory and engineering standpoint, however, they are not. A safety valve has fast-opening characteristics certified for gases, while a relief valve has a gradual-opening characteristic for liquids.\"}},{\"@type\":\"Question\",\"name\":\"What is set pressure?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It is the exact pressure point at which the valve is set to begin opening. In safety valves, full opening occurs almost immediately after this point is exceeded. In relief valves, full opening requires additional overpressure (generally 10% or 25% above the set pressure).\"}},{\"@type\":\"Question\",\"name\":\"What is a safety relief valve?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It is a hybrid term used to describe a versatile valve that can work either way depending on the application. It generally refers to a valve that opens rapidly (safety type) when used with gases, but can also open proportionally (relief type) when installed in a liquid system.\"}},{\"@type\":\"Question\",\"name\":\"Does the valve close at exactly the same pressure at which it opened?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"In relief valves, yes; they tend to close as soon as the pressure drops to the set level (set point). In safety valves, no; they need the pressure to fall significantly below the opening pressure (a margin known as blowdown or reseating differential) to ensure tight shutoff and to keep the valve from \u201cchattering\u201d or vibrating unstably.\"}},{\"@type\":\"Question\",\"name\":\"Where should the fluid released by each valve be discharged?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Because the safety valve releases toxic or hot fluid at high velocity, its outlet must always be routed to a safe location (such as a vent header or the atmosphere) where there is no backpressure to affect its popping. The relief valve, being part of process control, usually discharges the liquid through a return line to the storage tank or to the pump suction, recirculating the fluid without losing it.\"}}]}]}]","footnotes":"","_vg_translation_of":"472","_vg_lang":"en","_vg_wpml_state":"{\"lang\":\"en\",\"trid\":\"640\",\"src\":\"es\"}"},"categories":[37],"tags":[],"class_list":["post-685","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-relief-and-safety"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/posts\/685","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/comments?post=685"}],"version-history":[{"count":3,"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/posts\/685\/revisions"}],"predecessor-version":[{"id":10277,"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/posts\/685\/revisions\/10277"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/media\/227"}],"wp:attachment":[{"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/media?parent=685"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/categories?post=685"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/tags?post=685"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}