{"id":681,"date":"2025-12-15T16:33:39","date_gmt":"2025-12-15T15:33:39","guid":{"rendered":"https:\/\/www.valfonta.com\/blog\/how-it-regulate-a-pressure-reducing-valve\/"},"modified":"2026-10-07T12:33:11","modified_gmt":"2026-10-07T10:33:11","slug":"how-it-regulate-a-pressure-reducing-valve","status":"publish","type":"post","link":"https:\/\/www.valfonta.com\/en\/blog\/how-it-regulate-a-pressure-reducing-valve\/","title":{"rendered":"How do you adjust a pressure reducing valve?"},"content":{"rendered":"<div class=\"wp-block-group vf-raiz vf-pl-articulo is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-cat-wrap is-layout-flow wp-block-group-is-layout-flow\"><article class=\"wp-block-group vf-pdp vf-post is-layout-flow wp-block-group-is-layout-flow\"><nav class=\"wp-block-group vf-breadcrumbs vfa-aria-label--Breadcrumbs is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><a href=\"\/en\/\">Home<\/a><span class=\"vf-sep\">\u203a<\/span><a href=\"\/en\/blog\/\">Blog<\/a><span class=\"vf-sep\">\u203a<\/span><span aria-current=\"page\">How do you adjust a pressure reducing valve?<\/span><\/p><\/nav><header class=\"wp-block-group vf-post-head is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-pdp-eyebrow wp-block-paragraph\"><a href=\"\/en\/pressure-reducing-valves\/\">Pressure reducing valves<\/a><\/p><h1 class=\"wp-block-heading\">How do you adjust a pressure reducing valve?<\/h1><p class=\"vf-post-meta wp-block-paragraph\"><span>By Valfonta<\/span><span><time datetime=\"2026-09-29\">Updated September 29, 2026<\/time><\/span><span>9 min read<\/span><\/p><\/header><figure class=\"wp-block-image size-full vf-post-hero is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/como-regular-una-valvula-reductora-de-presion.webp\" alt=\"How do you adjust a pressure reducing valve?\" class=\"wp-image-226\" width=\"1200\" height=\"514\"\/><\/figure><div class=\"wp-block-group vf-post-grid is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-post-body is-layout-flow wp-block-group-is-layout-flow\"><aside class=\"wp-block-group vf-post-summary vfa-aria-label--In%20summary is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-t wp-block-paragraph\">In summary<\/p><p class=\"wp-block-paragraph\">A pressure reducing valve is adjusted by varying the spring compression with the adjusting screw or nut: turning it clockwise raises the outlet pressure and turning it counterclockwise lowers it. First, install inlet and outlet pressure gauges and a Y-strainer, and open the flow slowly to avoid water hammer. Fine adjustment is done with flow, starting with the spring relaxed and watching the outlet pressure gauge. The PRV30 and PRV45 models require an 8 mm Allen key; the M1, M2, PRV20, and PRV44 require an open-end wrench.<\/p><\/aside><details class=\"wp-block-details vf-post-toc-m is-layout-flow wp-block-details-is-layout-flow\"><summary>Article contents<\/summary><ol class=\"wp-block-list\"><li><a href=\"#guia-basica-para-la-regulacion-de-este-tipo-de-valvulas\">Basic guide to adjusting this type of valve<\/a><\/li><li><a href=\"#antes-de-empezar-condiciones-previas-para-una-regulacion-seg\">Before you start: prerequisites for safe adjustment<\/a><\/li><li><a href=\"#guia-paso-a-paso-el-procedimiento-de-ajuste-estandar\">Step-by-step guide: the standard adjustment procedure<\/a><\/li><li><a href=\"#particularidades-segun-el-modelo-valfonta-serie-m-vs-serie-p\">Specifics by Valfonta model (M Series vs. PRV Series)<\/a><\/li><li><a href=\"#tabla-de-referencia-rapida-herramientas-y-sentido-de-giro\">Quick reference table: tools and direction of rotation<\/a><\/li><li><a href=\"#problemas-comunes-durante-la-regulacion\">Common problems during adjustment<\/a><\/li><li><a href=\"#preguntas\">Frequently asked questions<\/a><\/li><\/ol><\/details><h2 class=\"wp-block-heading\" id=\"guia-basica-para-la-regulacion-de-este-tipo-de-valvulas\"><strong> Basic guide to adjusting this type of valve<\/strong><\/h2><p class=\"wp-block-paragraph\">Adjusting a pressure reducing valve is a simple but critical maintenance task. <\/p><p class=\"wp-block-paragraph\">The goal is to adjust the internal force of the mechanism so that the outlet pressure (\u201cdownstream\u201d) remains stable at the desired value, regardless of inlet fluctuations.<\/p><p class=\"wp-block-paragraph\"><strong>The quick answer:<\/strong> On the vast majority of <a href=\"\/en\/blog\/types-of-industrial-valves-2\/\">industrial valves<\/a>, including the Valfonta <strong>M<\/strong> and <strong>PRV<\/strong> series, adjustment is achieved by changing the compression of the main spring with an adjusting screw or nut.<\/p><p class=\"wp-block-paragraph\">To do it correctly, you only need to remember this <strong>golden rule<\/strong>:<\/p><div class=\"wp-block-group vf-t-ul is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>To raise the pressure (+):<\/strong> Turn the screw <strong>clockwise<\/strong> (to the right). This compresses the spring and exerts more force on the diaphragm or piston. Which one suits you? We cover it in our <a href=\"\/en\/blog\/piston-vs-diaphragm\/\">comparison of piston and diaphragm reducing valves<\/a>.<\/p><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>To lower the pressure (-):<\/strong> Turn the screw <strong>counterclockwise<\/strong> (to the left). This decompresses the spring and reduces the opposing force.<\/p><\/div><\/div><p class=\"wp-block-paragraph\">Although the concept is simple, adjusting the valve safely and accurately requires a few essential preliminary steps, which we detail below.<\/p><h2 class=\"wp-block-heading\" id=\"antes-de-empezar-condiciones-previas-para-una-regulacion-seg\"><strong>Before you start: prerequisites for safe adjustment<\/strong><\/h2><p class=\"wp-block-paragraph\">It is not simply a matter of grabbing a wrench and turning. Before working on the valve, it is essential to make sure the installation meets certain minimum conditions so that the reading is accurate and the equipment is not damaged.<\/p><h3 class=\"wp-block-heading\" id=\"1-instalacion-de-manometros-imprescindible\"><strong>1. Pressure gauge installation (essential)<\/strong><\/h3><p class=\"wp-block-paragraph\">You cannot adjust what you cannot measure. For correct adjustment, you need visibility of what is happening inside the pipe. As our installation diagrams show, you need <strong>two pressure gauges<\/strong>:<\/p><div class=\"wp-block-group vf-t-ul is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Inlet pressure gauge:<\/strong> To verify that sufficient pressure is reaching the valve.<\/p><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Outlet pressure gauge:<\/strong> This is the critical one. It must be located \u201cdownstream\u201d of the valve so you can see in real time how the pressure changes as you turn the screw.<\/p><\/div><\/div><h3 class=\"wp-block-heading\" id=\"2-limpieza-y-filtrado\"><strong>2. Cleaning and filtering<\/strong><\/h3><p class=\"wp-block-paragraph\">Before attempting to adjust a new or recently serviced valve, make sure the pipe is clean. A small metal chip or dirt lodged in the seat can prevent the valve from closing tightly, causing the pressure to rise uncontrollably and preventing fine adjustment. That is why we always recommend installing a <strong>Y-strainer<\/strong> immediately upstream of the reducing valve.<\/p><h3 class=\"wp-block-heading\" id=\"3-evitar-golpes-de-ariete\"><strong>3. Avoid water hammer<\/strong><\/h3><p class=\"wp-block-paragraph\">Never adjust the valve by opening the flow all at once. The isolation valves (inlet and outlet) must be opened <strong>slowly<\/strong>. A sudden pressure change can damage the valve\u2019s internal diaphragm or bellows before you even start adjusting.<\/p><h2 class=\"wp-block-heading\" id=\"guia-paso-a-paso-el-procedimiento-de-ajuste-estandar\"><strong>Step-by-step guide: the standard adjustment procedure<\/strong><\/h2><p class=\"wp-block-paragraph\">Once the installation has been checked, we can proceed with the adjustment. This procedure applies to most of our spring-loaded self-operated valves.<\/p><div class=\"wp-block-group vf-t-ul is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Step 1: Relax the spring (recommended).<\/strong> If this is the first start-up, it is advisable to start with the valve \u201crelaxed.\u201d Turn the adjusting screw or nut counterclockwise until you feel that the spring is exerting hardly any pressure. This ensures that the valve is closed or at its minimum pressure point when flow starts.<\/p><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Step 2: Open the flow slowly. <\/strong>Open the isolation valves (inlet and outlet) very slowly. This is vital to avoid <strong>water hammer<\/strong>, which could damage the valve internals. If the valve requires a <strong>condensate pot<\/strong> (for steam or fluids &gt;125 \u00b0C), make sure it has been filled with water until it overflows before this step.<\/p><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Step 3: Fine adjustment.<\/strong> With the fluid flowing (or with the valve static, depending on the process), start turning the adjusting element while closely watching the <strong>outlet pressure gauge<\/strong>.<\/p><ul class=\"wp-block-list\"><li><strong>To raise the pressure:<\/strong> Turn <strong>clockwise<\/strong> (right). In doing so, you are compressing the spring, which forces the valve to let more fluid through to balance that force.<\/li><li><strong>To lower the pressure:<\/strong> Turn <strong>counterclockwise<\/strong> (left). Decompressing the spring reduces the setting.<\/li><\/ul><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Extra tip:<\/strong> If you need to lower the pressure and have overshot, it is sometimes more effective to \u201cloosen\u201d the screw a little more than necessary and then \u201ctighten\u201d it again until you reach the exact point from below. This helps seat the spring correctly.<\/p><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Step 4: Verification.<\/strong> Once the desired pressure is reached on the gauge, lock the position (if the model has a locknut) and observe how the valve behaves when there is flow demand and when the demand is shut off.<\/p><\/div><\/div><h2 class=\"wp-block-heading\" id=\"particularidades-segun-el-modelo-valfonta-serie-m-vs-serie-p\"><strong>Specifics by Valfonta model <\/strong><strong>(M Series vs. PRV Series)<\/strong><\/h2><h3 class=\"wp-block-heading\" id=\"serie-m-modelos-industriales-m1-y-m2\"><strong>M Series (M1 and M2 industrial models)<\/strong><\/h3><p class=\"wp-block-paragraph\">These models are usually installed in larger-flow, larger-size applications.<\/p><div class=\"wp-block-group vf-t-ul is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>M1 model:<\/strong> Adjustment is made by turning the <strong>adjusting nut<\/strong> located at the top, above the spring.<\/p><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>M2 model:<\/strong> It has a hex-head <strong>adjusting screw<\/strong> at the top of the tower. <\/p><p class=\"wp-block-paragraph\">Remember that, after adjustment, the outlet pressure acts directly on the diaphragm to compensate.<\/p><\/div><\/div><h3 class=\"wp-block-heading\" id=\"serie-prv-valvulas-inoxidables\"><strong>PRV Series (stainless steel valves)<\/strong><\/h3><p class=\"wp-block-paragraph\">This range has more compact or hygienic designs and in some cases requires specific tools:<\/p><div class=\"wp-block-group vf-t-ul is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>PRV20 model:<\/strong> It is adjusted by turning the top <strong>adjusting nut<\/strong>.<\/p><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>PRV30 and PRV45 models:<\/strong> The design is more specific. To adjust the set point, you will need an <strong>8 mm Allen key<\/strong> to turn the internal adjusting nut\/screw.<\/p><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>PRV44 model:<\/strong> It uses a conventional <strong>adjusting screw<\/strong> located at the top of the cap.<\/p><\/div><\/div><h2 class=\"wp-block-heading\" id=\"tabla-de-referencia-rapida-herramientas-y-sentido-de-giro\"><strong>Quick reference table: tools and direction of rotation<\/strong><\/h2><p class=\"wp-block-paragraph\">To make your job easier, we have compiled in this table exactly which tool you need for each model in our catalog and how to operate it.<\/p><div class=\"wp-block-group vf-tbl-wrap is-layout-flow wp-block-group-is-layout-flow\"><figure class=\"wp-block-table vf-post-table\"><table><thead><tr><th><strong>Series \/ Model<\/strong><\/th><th><strong>Adjusting Element<\/strong><\/th><th><strong>Usual Tool<\/strong><\/th><th><strong>To raise pressure (+)<\/strong><\/th><th><strong>To lower pressure (-)<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>M1 model<\/strong><\/td><td>Top adjusting nut <\/td><td>Open-end \/ adjustable wrench<\/td><td>Clockwise (Compress) <\/td><td>Counterclockwise<\/td><\/tr><tr><td><strong>M2 model<\/strong><\/td><td>Adjusting screw (Hex head) <\/td><td>Open-end \/ adjustable wrench<\/td><td>Clockwise (Compress) <\/td><td>Counterclockwise<\/td><\/tr><tr><td><strong>PRV20 model<\/strong><\/td><td>Top adjusting nut <\/td><td>Open-end wrench<\/td><td>Clockwise (Compress) <\/td><td>Counterclockwise<\/td><\/tr><tr><td><strong>PRV30 model<\/strong><\/td><td>Internal adjusting nut <\/td><td>Allen key (8 mm) <\/td><td>Clockwise (Compress)<\/td><td>Counterclockwise<\/td><\/tr><tr><td><strong>PRV44 model<\/strong><\/td><td>Top adjusting screw <\/td><td>Open-end wrench<\/td><td>Clockwise (Compress)<\/td><td>Counterclockwise<\/td><\/tr><tr><td><strong>PRV45 model<\/strong><\/td><td>Internal adjusting nut <\/td><td>Allen key (8 mm) <\/td><td>Clockwise (Compress) <\/td><td>Counterclockwise<\/td><\/tr><\/tbody><\/table><\/figure><\/div><p class=\"wp-block-paragraph\"><i>*Note:<\/i><i> On all Valfonta models, the principle is universal: <\/i><i>Compressing the spring (clockwise) always increases the set pressure<\/i><i>.<\/i><\/p><h2 class=\"wp-block-heading\" id=\"problemas-comunes-durante-la-regulacion\"><strong> Common problems during adjustment <\/strong><\/h2><h3 class=\"wp-block-heading\" id=\"1-la-presion-sube-sola-cuando-cierro-el-consumo\"><strong>1. The pressure rises by itself when I shut off the demand<\/strong><\/h3><p class=\"wp-block-paragraph\">If you set the valve to 3 bar with the tap open, but when you close it the pressure on the gauge starts to rise slowly until it equals the inlet pressure, you have a tightness problem.<\/p><div class=\"wp-block-group vf-t-ul is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Probable cause:<\/strong> Dirt or impurities lodged between the seat and the plug, preventing tight shutoff. It may also be due to a plug eroded by use.<\/p><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Solution:<\/strong> Remove the cover, inspect the seat, and clean it or replace it if it is damaged. <i>Remember: an upstream strainer is vital to prevent this.<\/i><\/p><\/div><\/div><h3 class=\"wp-block-heading\" id=\"2-la-presion-oscila-mucho-inestabilidad\"><strong>2. The pressure fluctuates a lot (Instability)<\/strong><\/h3><p class=\"wp-block-paragraph\">If the gauge needle constantly rises and falls (cycling), adjustment is impossible.<\/p><div class=\"wp-block-group vf-t-ul is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><strong>Probable cause:<\/strong><\/p><ul class=\"wp-block-list\"><li>The control line tapping (if external) is too close to the valve, in a turbulent zone.<\/li><li>The valve is oversized for the actual flow passing through it.<\/li><\/ul><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><strong>Solution:<\/strong><\/p><ul class=\"wp-block-list\"><li>Make sure the pressure sensing point is <strong>at least 1 meter<\/strong> from the valve outlet.<\/li><\/ul><\/div><\/div><p class=\"wp-block-paragraph\">Install a <strong>needle valve<\/strong> in the control line to \u201cdampen\u201d the signal and stabilize the reading.<\/p><h3 class=\"wp-block-heading\" id=\"3-no-consigo-llegar-a-la-presion-deseada\"><strong>3. I cannot reach the desired pressure<\/strong><\/h3><p class=\"wp-block-paragraph\">You turn the screw all the way, but the pressure does not rise enough, or you loosen it completely and the pressure is still too high.<\/p><div class=\"wp-block-group vf-t-ul is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Probable cause:<\/strong> The installed spring does not match the pressure range you need. Reducing valves work with different interchangeable springs to cover specific ranges (e.g., 1 to 8 bar, or 4 to 12 bar).<\/p><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><i><\/i><\/p><p class=\"wp-block-paragraph\"><strong>Solution:<\/strong> Check the valve nameplate to confirm the spring range (\u201cRANGE\u201d). If it is out of range, contact Valfonta to purchase the right spring.<\/p><\/div><\/div><p class=\"wp-block-paragraph\">You will find all models, with their pressure ranges and materials, on our <a href=\"\/en\/pressure-reducing-valves\/\">pressure reducing valves<\/a> page.<\/p><h3 class=\"wp-block-heading\" id=\"necesita-ayuda-de-nuestros-tecnicos-para-la-regulacion-de-su\"><strong>Need help from our technicians to adjust your valve?<\/strong><\/h3><p class=\"wp-block-paragraph\">Correct adjustment not only ensures that your process runs at the exact pressure required, but also extends the service life of the entire installation, protecting pipes, filters, and sensitive machinery.<\/p><section id=\"preguntas\" class=\"wp-block-group vf-post-faq is-layout-flow wp-block-group-is-layout-flow\"><h2 class=\"wp-block-heading\">Frequently asked questions<\/h2><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Should I adjust the valve with flow (dynamic) or without flow (static)?<\/summary><div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><p class=\"wp-block-paragraph\">\u00a0The general recommendation is to make the fine adjustment under <strong>dynamic<\/strong> conditions, that is, with a demand flow representative of your normal process. Reducing valves have a slight difference between the pressure at zero flow (lockup pressure) and the pressure with flow. If you set it under static conditions, the pressure may drop slightly below the desired value when you open the taps or machines \u201cdownstream.\u201d<\/p><\/div><\/details><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>I have tightened the screw all the way and cannot reach the desired pressure. What is happening?<\/summary><div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><p class=\"wp-block-paragraph\">If you have reached the end of the screw\u2019s travel and the outlet pressure is still low, <strong>do not force the mechanism<\/strong>. Most likely, the spring installed in your valve does not cover the range you need (for example, you have a 0.5-3 bar spring and need to reach 5 bar). You should contact Valfonta to purchase the right spring for your new operating range.<\/p><\/div><\/details><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Why must the water seal pot be filled with water before adjusting on steam?<\/summary><div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><p class=\"wp-block-paragraph\">In applications with steam or fluids above 125\u00b0C, the water seal pot (condensate pot) acts as a thermal barrier. If you try to adjust the valve without first filling it with water until it overflows, the steam will come into direct contact with the actuator\u2019s elastomeric diaphragm and can burn or deform it instantly, making adjustment impossible.<\/p><\/div><\/details><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Does the mounting position affect adjustment accuracy?<\/summary><div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><p class=\"wp-block-paragraph\">Yes. Although models such as the PRV series allow some flexibility, the standard position (horizontal pipe, vertical actuator) ensures the best sensitivity and the least wear. Installing the valve with the actuator \u201clying down\u201d (horizontal axis) is not recommended, as the weight of the internals and side friction can cause erratic adjustment or hysteresis.<\/p><\/div><\/details><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>What is the external control line for on models such as the M1?<\/summary><div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><p class=\"wp-block-paragraph\">The control line transmits the actual pressure in the outlet pipe to the diaphragm so that the valve \u201cknows\u201d when to close or open. On models that require an external line (such as the M1, or the M2 on steam), it is vital to connect it <strong>at least 1 meter<\/strong> from the outlet. If it is connected too close, fluid turbulence will distort the reading, causing the valve to oscillate and not regulate stably.<\/p><\/div><\/details><details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Does the valve need to be recalibrated over time?<\/summary><div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><p class=\"wp-block-paragraph\">\u00a0Self-operated valves are very stable and do not require continuous maintenance. However, springs may relax slightly after years of service or intensive cycling. We recommend checking the pressure on the outlet pressure gauge periodically and, if a deviation is observed, slightly retightening the adjusting screw to compensate.<\/p><\/div><\/details><\/section><\/div><aside class=\"wp-block-group vf-post-aside is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-post-sticky is-layout-flow wp-block-group-is-layout-flow\"><nav class=\"wp-block-group vf-post-toc vfa-aria-label--Article%20contents is-layout-flow wp-block-group-is-layout-flow\"><p class=\"wp-block-paragraph\">In this article<\/p><ol class=\"wp-block-list\"><li><a href=\"#guia-basica-para-la-regulacion-de-este-tipo-de-valvulas\">Basic guide to adjusting this type of valve<\/a><\/li><li><a href=\"#antes-de-empezar-condiciones-previas-para-una-regulacion-seg\">Before you start: prerequisites for safe adjustment<\/a><\/li><li><a href=\"#guia-paso-a-paso-el-procedimiento-de-ajuste-estandar\">Step-by-step guide: the standard adjustment procedure<\/a><\/li><li><a href=\"#particularidades-segun-el-modelo-valfonta-serie-m-vs-serie-p\">Specifics by Valfonta model (M Series vs. PRV Series)<\/a><\/li><li><a href=\"#tabla-de-referencia-rapida-herramientas-y-sentido-de-giro\">Quick reference table: tools and direction of rotation<\/a><\/li><li><a href=\"#problemas-comunes-durante-la-regulacion\">Common problems during adjustment<\/a><\/li><li><a href=\"#preguntas\">Frequently asked questions<\/a><\/li><\/ol><\/nav><div class=\"wp-block-group vf-post-cta is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-t wp-block-paragraph\">Do you need a pressure reducing valve?<\/p><p class=\"wp-block-paragraph\">We help you choose the right model and size for your installation.<\/p><p class=\"vf-envolt wp-block-paragraph\"><a class=\"vf-btn vf-btn--pri\" href=\"#contactar\">Request a quote<\/a><\/p><p class=\"vf-envolt wp-block-paragraph\"><a class=\"vf-btn vf-btn--sec\" href=\"\/en\/pressure-reducing-valves\/\">View pressure reducing valves<\/a><\/p><p class=\"vf-tel wp-block-paragraph\">Or call <a href=\"tel:+34933720888\">933 720 888<\/a><\/p><\/div><\/div><\/aside><\/div><section id=\"valvulas\" class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><h2 class=\"wp-block-heading\">Related valves<\/h2><ul class=\"vf-rel wp-block-list\"><li><a href=\"\/en\/product\/pressure-reducing-valves-m1\/\"><img decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/valvula-reductora-presion-m1-perspectiva-400.webp\" alt=\"M1 reducing valve\" class=\"wp-image-201\" width=\"300\" height=\"300\" loading=\"lazy\"><b>M1 reducing valve<\/b><span>Up to DN150 and 220 \u00b0C, for steam.<\/span><\/a><\/li><li><a href=\"\/en\/product\/pressure-reducing-valve-vd\/\"><img decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/valvula-reductora-presion-vd-perspectiva-400.webp\" alt=\"VD reducing valve\" class=\"wp-image-10116\" width=\"300\" height=\"300\" loading=\"lazy\"><b>VD reducing valve<\/b><span>From DN15 to DN100, up to 40 bar, and steam up to 200 \u00b0C.<\/span><\/a><\/li><li><a href=\"\/en\/product\/pressure-reducing-valve-prv30\/\"><img decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/valvula-reductora-presion-prv30-frontal-400.webp\" alt=\"PRV30 reducing valve\" class=\"wp-image-199\" width=\"300\" height=\"300\" loading=\"lazy\"><b>PRV30 reducing valve<\/b><span>316L stainless, from DN15 to DN25, threaded or flanged, up to 25 bar.<\/span><\/a><\/li><\/ul><p class=\"vf-post-more wp-block-paragraph\"><a href=\"\/en\/pressure-reducing-valves\/\">View all pressure reducing valves \u2192<\/a><\/p><\/section><section id=\"articulos\" class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><h2 class=\"wp-block-heading\">Related articles<\/h2><div class=\"wp-block-group vf-post-cards vf-t-ul is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-amb-enllac is-layout-flow wp-block-group-is-layout-flow\"><figure class=\"wp-block-image vf-img-suelta\"><img decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/detalle-eyector-Valfonta.jpg\" alt=\"\" class=\"wp-image-231\" width=\"400\" height=\"225\" loading=\"lazy\"><\/figure><div class=\"wp-block-group vf-in is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><small>Pressure reducing valves<\/small><b>Where should a pressure reducing valve be installed?<\/b><span>6 min read<\/span><\/p><\/div><p class=\"vf-enllac wp-block-paragraph\"><a class=\"vf-enllac-estirat\" href=\"\/en\/blog\/where-the-pressure-reducing-valve-is-placed\/\" aria-label=\"Pressure reducing valves Where should a pressure reducing valve be installed? 6 min read\"><\/a><\/p><\/div><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-amb-enllac is-layout-flow wp-block-group-is-layout-flow\"><figure class=\"wp-block-image vf-img-suelta\"><img decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/valvula-reductora-que-es.webp\" alt=\"\" class=\"wp-image-247\" width=\"400\" height=\"225\" loading=\"lazy\"><\/figure><div class=\"wp-block-group vf-in is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><small>Pressure reducing valves<\/small><b>What is a steam pressure reducing valve?<\/b><span>14 min read<\/span><\/p><\/div><p class=\"vf-enllac wp-block-paragraph\"><a class=\"vf-enllac-estirat\" href=\"\/en\/blog\/pressure-reducing-valve-for-steam-valfonta\/\" aria-label=\"Pressure reducing valves What is a steam pressure reducing valve? 14 min read\"><\/a><\/p><\/div><\/div><div class=\"wp-block-group vf-t-li is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-amb-enllac is-layout-flow wp-block-group-is-layout-flow\"><figure class=\"wp-block-image vf-img-suelta\"><img decoding=\"async\" src=\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/como-instalar-una-valvula-reductora-de-presion-de-agua1.png.jpg\" alt=\"\" class=\"wp-image-242\" width=\"400\" height=\"225\" loading=\"lazy\"><\/figure><div class=\"wp-block-group vf-in is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><small>Pressure reducing valves<\/small><b>How do you install a water pressure reducing valve?<\/b><span>5 min read<\/span><\/p><\/div><p class=\"vf-enllac wp-block-paragraph\"><a class=\"vf-enllac-estirat\" href=\"\/en\/blog\/how-to-install-pressure-reducing-valve\/\" aria-label=\"Pressure reducing valves How do you install a water pressure reducing valve? 5 min read\"><\/a><\/p><\/div><\/div><\/div><\/section><section id=\"contactar\" class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group vf-quote is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\"><h2 class=\"wp-block-heading\">Can we help with your installation?<\/h2><p class=\"wp-block-paragraph\">Tell us the fluid, the inlet and outlet pressures, the temperature, and the flow rate, and we will recommend the right valve.<\/p><p class=\"vf-pdp-contact wp-block-paragraph\">You can also call <a href=\"tel:+34933720888\">933 720 888<\/a> or email <a href=\"mailto:valfonta@valfonta.com\">valfonta@valfonta.com<\/a>.<\/p><\/div>\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f535-o1\" lang=\"en-US\" dir=\"ltr\" data-wpcf7-id=\"535\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/en\/wp-json\/wp\/v2\/posts\/681#wpcf7-f535-o1\" method=\"post\" class=\"wpcf7-form init vf-form wpcf7-acceptance-as-validation\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\" toolname=\"consulta_contacto\" tooldescription=\"Send an enquiry to Valfonta, industrial valve manufacturer; a member of the team will reply.\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"535\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.2.5\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f535-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/><input type=\"hidden\" name=\"_vf_t\" value=\"1795901413.5f50901c2e12e1c5\" \/>\n<\/fieldset>\n<label>Name *<span class=\"wpcf7-form-control-wrap\" data-name=\"nombre\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" autocomplete=\"name\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"nombre\" \/><\/span><\/label><label>Company<span class=\"wpcf7-form-control-wrap\" data-name=\"empresa\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text\" autocomplete=\"organization\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"empresa\" \/><\/span><\/label><label>Email *<span class=\"wpcf7-form-control-wrap\" data-name=\"email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" autocomplete=\"email\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"email\" name=\"email\" \/><\/span><\/label><label>Phone<span class=\"wpcf7-form-control-wrap\" data-name=\"telefono\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-tel wpcf7-text wpcf7-validates-as-tel\" autocomplete=\"tel\" aria-invalid=\"false\" value=\"\" type=\"tel\" name=\"telefono\" \/><\/span><\/label><label class=\"vf-full\">Reason for your inquiry<span class=\"wpcf7-form-control-wrap\" data-name=\"motivo\"><select class=\"wpcf7-form-control wpcf7-select\" aria-invalid=\"false\" name=\"motivo\"><option value=\"\">Select<\/option><option value=\"Request a quote\">Request a quote<\/option><option value=\"Technical advice on choosing a valve\">Technical advice on choosing a valve<\/option><option value=\"Spare parts or repair\">Spare parts or repair<\/option><option value=\"Documentation or certificates\">Documentation or certificates<\/option><option value=\"Other\">Other<\/option><\/select><\/span><\/label><label class=\"vf-full\">Message *<span class=\"wpcf7-form-control-wrap\" data-name=\"mensaje\"><textarea cols=\"40\" rows=\"5\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Tell us what you need: fluid, pressures, flow rate, model, or serial number\u2026\" name=\"mensaje\"><\/textarea><\/span><\/label><label class=\"vf-chk vf-full\"><span class=\"wpcf7-form-control-wrap\" data-name=\"privacidad\"><span class=\"wpcf7-form-control wpcf7-acceptance\"><span class=\"wpcf7-list-item\"><input type=\"checkbox\" name=\"privacidad\" value=\"1\" aria-invalid=\"false\" \/><\/span><\/span><\/span> <span>I have read and accept the <a href=\"\/en\/privacy-policy\/\">privacy policy<\/a> *<\/span><\/label><input class=\"wpcf7-form-control wpcf7-submit has-spinner vf-btn vf-btn--pri\" type=\"submit\" value=\"Send message\" \/><span class=\"vf-hp\" aria-hidden=\"true\"><label>Web <input type=\"text\" name=\"vf_web\" value=\"\" tabindex=\"-1\" autocomplete=\"off\" toolparamdescription=\"Campo de control: d\u00e9jalo vac\u00edo\"><\/label><\/span><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n\n<\/div><\/section><div class=\"wp-block-group vf-pdp-bar is-layout-flow wp-block-group-is-layout-flow\"><p class=\"vf-envolt wp-block-paragraph\"><a class=\"vf-btn vf-btn--sec\" href=\"tel:+34933720888\">Call<\/a><a class=\"vf-btn vf-btn--pri\" href=\"#contactar\">Request a quote<\/a><\/p><\/div><\/article><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>A pressure reducing valve is adjusted by changing the spring compression with the adjusting screw or nut: turning it clockwise raises the outlet pressure, and turning it counterclockwise lowers it.<\/p>\n","protected":false},"author":1,"featured_media":226,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_generate-full-width-content":"true","_generate-disable-headline":"true","rank_math_title":"How to adjust a pressure reducing valve | Valfonta","rank_math_description":"How to adjust a pressure reducing valve. Strengths, features, and particulars of Valfonta models. Let\u2019s talk.","rank_math_focus_keyword":"","vf_jsonld":"[{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.valfonta.com\/#organization\",\"name\":\"Valfonta\",\"legalName\":\"Val Fonta, S.L.\",\"taxID\":\"B59935718\",\"url\":\"https:\/\/www.valfonta.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/valfonta-logo.webp\"},\"foundingDate\":\"1962\",\"email\":\"valfonta@valfonta.com\",\"telephone\":\"+34 933 720 888\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"C\/ Bronze 26, Pol. Ind. Les Guixeres\",\"postalCode\":\"08915\",\"addressLocality\":\"Badalona\",\"addressRegion\":\"Barcelona\",\"addressCountry\":\"ES\"},\"description\":\"Design, manufacture, and sale of pressure reducing valves, pressure relief valves, and control valves.\"},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.valfonta.com\/#website\",\"url\":\"https:\/\/www.valfonta.com\/en\/\",\"name\":\"Valfonta\",\"publisher\":{\"@id\":\"https:\/\/www.valfonta.com\/#organization\"},\"inLanguage\":\"en\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.valfonta.com\/en\/blog\/how-it-regulate-a-pressure-reducing-valve\/#webpage\",\"url\":\"https:\/\/www.valfonta.com\/en\/blog\/how-it-regulate-a-pressure-reducing-valve\/\",\"name\":\"How to adjust a pressure reducing valve | Valfonta\",\"description\":\"How to adjust a pressure reducing valve. Strengths, features, and particulars of Valfonta models. Let\u2019s talk.\",\"isPartOf\":{\"@id\":\"https:\/\/www.valfonta.com\/#website\"},\"about\":{\"@id\":\"https:\/\/www.valfonta.com\/#organization\"},\"inLanguage\":\"en\",\"datePublished\":\"2025-12-15T16:33:39+02:00\",\"dateModified\":\"2026-09-29T12:00:00+02:00\",\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/como-regular-una-valvula-reductora-de-presion.webp\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.valfonta.com\/en\/blog\/how-it-regulate-a-pressure-reducing-valve\/#breadcrumb\"}},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/como-regular-una-valvula-reductora-de-presion.webp\",\"url\":\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/como-regular-una-valvula-reductora-de-presion.webp\",\"caption\":\"How do you adjust a pressure reducing valve?\",\"inLanguage\":\"en\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/como-regular-una-valvula-reductora-de-presion.webp\",\"url\":\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/como-regular-una-valvula-reductora-de-presion.webp\",\"width\":\"1000\",\"height\":\"1000\",\"caption\":\"How to adjust a pressure reducing valve\",\"inLanguage\":\"en\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.valfonta.com\/en\/blog\/how-it-regulate-a-pressure-reducing-valve\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.valfonta.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\/\/www.valfonta.com\/en\/blog\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"How do you adjust a pressure reducing valve?\",\"item\":\"https:\/\/www.valfonta.com\/en\/blog\/how-it-regulate-a-pressure-reducing-valve\/\"}]},{\"@type\":\"BlogPosting\",\"datePublished\":\"2025-12-15T16:33:39+02:00\",\"dateModified\":\"2026-09-29T12:00:00+02:00\",\"articleSection\":\"Pressure reducing valves\",\"@id\":\"https:\/\/www.valfonta.com\/en\/blog\/how-it-regulate-a-pressure-reducing-valve\/#schema-32381\",\"isPartOf\":{\"@id\":\"https:\/\/www.valfonta.com\/en\/blog\/how-it-regulate-a-pressure-reducing-valve\/#webpage\"},\"publisher\":{\"@id\":\"https:\/\/www.valfonta.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.valfonta.com\/wp-content\/uploads\/2026\/10\/como-regular-una-valvula-reductora-de-presion.webp\"},\"inLanguage\":\"en\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.valfonta.com\/en\/blog\/how-it-regulate-a-pressure-reducing-valve\/#webpage\"},\"headline\":\"How do you adjust a pressure reducing valve?\",\"name\":\"How to adjust a pressure reducing valve | Valfonta\",\"description\":\"How to adjust a pressure reducing valve. Strengths, features, and particulars of Valfonta models. Let\u2019s talk.\",\"author\":{\"@id\":\"https:\/\/www.valfonta.com\/#organization\"},\"abstract\":\"A pressure reducing valve is adjusted by varying the spring compression with the adjusting screw or nut: turning it clockwise raises the outlet pressure and turning it counterclockwise lowers it. First, install inlet and outlet pressure gauges and a Y-strainer, and open the flow slowly to avoid water hammer. Fine adjustment is done with flow, starting with the spring relaxed and watching the outlet pressure gauge. The PRV30 and PRV45 models require an 8 mm Allen key; the M1, M2, PRV20, and PRV44 require an open-end wrench.\"},{\"@type\":\"FAQPage\",\"@id\":\"https:\/\/www.valfonta.com\/en\/blog\/how-it-regulate-a-pressure-reducing-valve\/#faq\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Should I adjust the valve with flow (dynamic) or without flow (static)?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The general recommendation is to make the fine adjustment under dynamic conditions, that is, with a demand flow representative of your normal process. Reducing valves have a slight difference between the pressure at zero flow (lockup pressure) and the pressure with flow. If you set it under static conditions, the pressure may drop slightly below the desired value when you open the taps or machines \u201cdownstream.\u201d\"}},{\"@type\":\"Question\",\"name\":\"I have tightened the screw all the way and cannot reach the desired pressure. What is happening?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"If you have reached the end of the screw\u2019s travel and the outlet pressure is still low, do not force the mechanism. Most likely, the spring installed in your valve does not cover the range you need (for example, you have a 0.5-3 bar spring and need to reach 5 bar). You should contact Valfonta to purchase the right spring for your new operating range.\"}},{\"@type\":\"Question\",\"name\":\"Why must the water seal pot be filled with water before adjusting on steam?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"In applications with steam or fluids above 125\u00b0C, the water seal pot (condensate pot) acts as a thermal barrier. If you try to adjust the valve without first filling it with water until it overflows, the steam will come into direct contact with the actuator\u2019s elastomeric diaphragm and can burn or deform it instantly, making adjustment impossible.\"}},{\"@type\":\"Question\",\"name\":\"Does the mounting position affect adjustment accuracy?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Although models such as the PRV series allow some flexibility, the standard position (horizontal pipe, vertical actuator) ensures the best sensitivity and the least wear. Installing the valve with the actuator \u201clying down\u201d (horizontal axis) is not recommended, as the weight of the internals and side friction can cause erratic adjustment or hysteresis.\"}},{\"@type\":\"Question\",\"name\":\"What is the external control line for on models such as the M1?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The control line transmits the actual pressure in the outlet pipe to the diaphragm so that the valve \u201cknows\u201d when to close or open. On models that require an external line (such as the M1, or the M2 on steam), it is vital to connect it at least 1 meter from the outlet. If it is connected too close, fluid turbulence will distort the reading, causing the valve to oscillate and not regulate stably.\"}},{\"@type\":\"Question\",\"name\":\"Does the valve need to be recalibrated over time?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Self-operated valves are very stable and do not require continuous maintenance. However, springs may relax slightly after years of service or intensive cycling. We recommend checking the pressure on the outlet pressure gauge periodically and, if a deviation is observed, slightly retightening the adjusting screw to compensate.\"}}]}]}]","footnotes":"","_vg_translation_of":"470","_vg_lang":"en","_vg_wpml_state":"{\"lang\":\"en\",\"trid\":\"636\",\"src\":\"es\"}"},"categories":[36],"tags":[],"class_list":["post-681","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pressure-reducing-valves"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/posts\/681","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/comments?post=681"}],"version-history":[{"count":2,"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/posts\/681\/revisions"}],"predecessor-version":[{"id":10173,"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/posts\/681\/revisions\/10173"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/media\/226"}],"wp:attachment":[{"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/media?parent=681"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/categories?post=681"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.valfonta.com\/en\/wp-json\/wp\/v2\/tags?post=681"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}